Kemtrak

On-line sıvı ve gaz konsantrasyonu ölçüm

Kemtrak gerçek zamanlı konsantrasyon, renk ve yoğunluk kontrolü için endüstriyel fotometrik çözümleyicilerin ürün üretmektedir.

Basit ve sıfır bakım kullanımlı

 

Main features:
  • Real time, in-line measurement
  • Color & Concentration: 280 - 1050 nm
  • Zero maintenance
  • Long life LED lamps
  • Fiber optics - high perormance, instrinsically safe
  • Extensive range of robust fiber optic measurement
    cells - no electronics, moving parts or heat
  • Alarm signals for data and system failures
  • Inbuilt PID Controller
  • Data & system event logger for quality control
  • PC downloading software (Windows 2000, XP & Vista)
     
  • Analogue output (0/4-20 mA)
  • Supply voltage 110/240 VAC
  • IP65 protection
  • ATEX I I 2 GD EExd-IIB-T5 I (optional)
  • Overall dimensions:220 x 120 x 100 mm (LxWxD)
 

DCP007 Industrial Photometer

The Kemtrak DCP007 is an industrial UV-VIS-NIR fiber optic photometer designed to accurately measure the concentration of light absorbing substances.

The Kemtrak DCP007 uses a combination of long life, solid state LED lamps with fiber optics that provide a measurement with very high precision. Thanks to a proprietary dual wavelength four channel measurement technique and advanced digital electronics design, high concentration to ppm trace analysis is no problem. The primary “absorbing” wavelength measures any changes in the process medium, while the second reference wavelength, which is not absorbed by the process medium, compensates for turbidity and/or fouling of the optical windows.

Since optic fibers are used to pipe light to the measurement point and back, the measurement cell contains no electronics, moving parts or sources of heat that result in condensation on the optical surfaces. Standard measurement cells are machined in sanitary grade stainless steel with sapphire glass.

Measurement flanges- DIN Flange DN25, ISO DN25 TriClamp & ISO DN50 TriClamp.

The Kemtrak DCP007 color & concentration analyzer consists of three components:

  1. Control Unit. The control unit contains all electronics including light source and detectors.
  2. Flow Cell. In-line (flow through) measurement cell.
  3. Fibre Optics. Industrial grade fibre optic assembly connects the control unit to the flow-cell.

 

The configuration shown here is a 316 stainless steel DN25 DIN Flange flow cell with stainless steel fully interlocked fibre optic assembly. Both flowcell and fibres can withstand 200°

 

The Kemtrak DCP007 photometer measures at two wavelengths. A primary "absorbing" wavelength is used to measure the substance being monitored while a "non absorbing" reference wavelength is used to compensate for turbidity, air bubbles and/or fouling.

Fiber optics are used to shine a precisely focused light beam through the process medium and back to a silicon photo-detector. A second photo-detector is used directly on the lamps to compensate for temperature effects and aging. The resulting measurements are very accurate with low drift and long-term calibration stability.

The attenuation of the transmitted light beam caused by light absorbing substances in the process medium is mathematically described by the Beer-Lambert law.

Applying the Beer-Lambert law (below), the concentration of the sample can be calculated.

 

A = ε l c
 
where:
   
A
=
absorbance (= - log transmittance)
   
ε
=
molar absorptivity coefficient
   
l
=
optical path length
   
c
=
concentration of absorbing species

 

The Kemtrak DCP007 photometer is ideally suited for industrial environments where simplicity, stability and zero maintenance is vital.

 

Main features:

  • 1000 - 2000 nm dual-wavelength detection*
  • Long life semiconductor light source
  • Simple & robust flowcell design using fibre optics - no electricity or heat near the sample
  • Easy to operate - four push buttons, user-friendly menu and alphanumeric display
  • Two alarms (high/low) and system fault monitoring
  • PID Controller (pulse width modulated relay or
    4-20 mA analogue output)
  • Cleaning sequence control (relay output)
  • Relays are protected with PTC resistor fuses (reset by disconnection of power supply)
  • Analogue output (0-20/4-20 mA)
  • Supply voltage 110/240 VAC
  • IP65 protection
  • Overall dimensions:220 x 120 x 100 mm (LxWxD)

* wavelengths must be factory installed
 

 


DCP007NIR Industrial Photometer

The Kemtrak DCP007NIR is an advanced dual wavelength photometer designed to accurately measure the concentration of liquids and gasses with near-infrared (NIR) absorbance from 1000 to 2000 nm.

Examples of NIR measurements include water, ethanol, sodium hydroxide, ethylene glycol, acetic acid and continuous fuel identification.

Optic fibers are utilized to pipe the light from within the DCP007NIR enclosure to the sampling point and back. This is a major benefit as all the electricity is kept within the analyzer enclosure permitting safe operation in even the most hazardous of environments. An additional benefit is that the light source is "cold" and does not affect the sample.

DIN Flange (DN25 & DN50) sensor flanges with 10mm optical path length

Optic fibres can be ordered in lengths up to 50m and are well suited for harsh industrial environments. Our standard fibers have a silicone-coated steel jacketing and can withstand temperatures up to 200 °C. A range of flow-cell manifolds are also available dependent upon the process and application.

Please contact a Kemtrak sales representative for more information.

  CE Compliant
  Quality Certificate
Development, production and
testing to ISO 9001.
 

ATEX Certified
Explosion protection available.

 

The Kemtrak DCP007NIR color & concentration analyzer consists of three components:

  1. Control Unit. The control unit contains all electronics including light source and detectors.
  2. Flow Cell. In-line (flow through) measurement cell.
  3. Fibre Optics. Industrial grade fibre optic assembly connects the control unit to the flow-cell.

 

The configuration shown here is a 316 stainless steel DN25 flow cell with stainless steel fully interlocked fibre optic assembly. Both flowcell and fibres can withstand 200°C

 

 

The Kemtrak DCP007NIR uses fiber optics to shine a precisely focused monochromatic (single wavelength) light beam through the process medium and back to a silicon photo-detector.

The attenuation of the transmitted light beam caused by light absorbing substances in the process medium is mathematically described by the Beer-Lambert law.

Applying the Beer-Lambert law (below), the concentration of the sample can be calculated.

A = ε l c
 
where:
   
A
=
absorbance (= - log transmittance)
   
ε
=
molar absorptivity coefficient
   
l
=
optical path length
   
c
=
concentration of absorbing species

 

TC007 Industrial Turbidimeter

The Kemtrak TC007 is a robust in-line fiber optic
turbidimeter designed to accurately measure the
concentration of light scattering components for a wide range of industrial process applications.

The Kemtrak TC007 measures attenuated light and/
or scattered light which is mathematically combined
using a ratio algorithm to accurately monitor the
turbidity of the sample. The Kemtrak TC007 can be configured to use the nephelometric method of turbidity measurement in accordance with International Standard ISO7027:1999(E).

Optic fibers are used to pipe the light from within the TC007 enclosure to the sampling point and back. This is a major benefit as all the electricity is kept within the analyzer enclosure permitting safe operation in even the most hazardous of environments.

The Kemtrak TC007 has an easy to use menu based software with a user configurable display that shows the turbidity value in real time. Additionally, the TC007 has a database and event handler to capture vital process information for use in quality assurance and plant control reports. All data is easily transferable to a PC via a USB interface.

DN50 TriClamp measurement cell

Main features:

  • Real time, in-line measurement
  • Long life 880nm LED lightsource
  • Zero maintenance
  • Fiber optics - high perormance, instrinsically safe
  • Extensive range of robust fiber optic measurement cells - no electronics, moving parts or heat
  • Alarm signals for data and system failures
  • Inbuilt PID Controller
  • Data & system event logger for quality control
  • PC downloading software (Windows 2000, XP & Vista)
     
  • Analogue output (0/4-20 mA)
  • Supply voltage 110/240 VAC
  • IP65 protection
  • ATEX I I 2 GD EExd-IIB-T5 I (optional)
  • Overall dimensions:220 x 120 x 100 mm (LxWxD

 

Downloading utility

All Kemtrak analyzers have an inbuilt database and event logger that capture vital process information for use in quality assurance and plant control reports. The inbuilt database also allows Kemtrak analyzers to be used as stand alone instrument.

Simple to use - graphical user interface

All data is easily transferred to a PC via a USB interface and a simple to use data downloading utility that is included with all kemtrak analyzers.

 

 

Main features:

Download settings, data log & event log from Kemtrak analyzers to a PC

Generate .xml (Excel) or .csv spreadsheet data files

Data logger can be configured to save from 1s to 24hr intervals (2hr to 20year capacity). At each interval the following is logged:

Timestamp

Measured value - the average, minimum and maximum for the selected logging interval

Measurement unit

Cleaning, alarms, digital input, zeroing, value held, system OK

PID values - enabled, set point, average, minimum & maximum output for the selected logging interval

Event logger stores more than 10,000 events, such as alarms, zeroing, cleaning, calibration & system events (power, system warning & error messages) and the exact time they occurred

USB data connection

Windows 2000, XP & Vista compatible

USB Interface

Windows 2000, XP & Vista compatible

MS Excel compatible

 

Kemtrak  Ürünleri ile uygun rekabetçi fiyaları almak için müşteri temsilçimiz ile  http://www.imajteknik.com.tr/bize-ulasin veya Fiyat teklifi formunu doldurarak mesaj bırakmanız halinde satış muhendislerimiz en kısa zamanda sizinle irtibat kuracaklardır.

Kemtrak markasına ait tüm ürünler

    0 kayıt bulundu

      ALFABETİK MARKA LİSTESİ

      Sertifikalarımız

      Oruçreis Mah. Tekstilkent Tic. Mrk.
      G2 Blok, No:101 (10AD-Z77)
      34235 Esenler / ISTANBUL
      T: +90 212 235 95 35 / 36
      F: +90 212 235 95 37

      info@imajteknik.com

      E-Bülten Listemize üye olun !

      Gelişmelerden haberdan olmak ve ileride gerçekleştirilecek yeniliklerimizden haberdan olabilmek için e-posta adresinizi bizimle paylaşın!