			 Draw Wire 
			  
			- Range 50 - 50000 mm 
			- Accuracy 0,05% - 0,25% 
			- Resolution 0,1 - 1 mm 
			- Output 10V, 4-20mA, A/B/Z, SSI, CAN, Par. 
			- Measurement through draw wire 
			 | 
			  | 
			
			   
			 | 
			
			 Inductive Gauge LVDT 
			  
			- Range 2 - 600 mm 
			- Accuracy 0,1% - 0,3% 
			- Resolution 5 - 200 µm 
			- Output 5V, 10V, bipolar, 4-20mA 
			- Measurement through free core, guided or sprung loaded push rod 
			 | 
		
		
			|   | 
		
		
			| 
			   
			 | 
			
			 Eddy Current Probe 
			  
			- Range 0,5 - 8 mm 
			- Accuracy 0,25% 
			- Resolution 100 - 1000 nm 
			- Output 5V, 10V, bipolar, CAN 
			- Contactless measurement at metallic objects 
			 | 
			  | 
			
			   
			 | 
			
			 Laser 
			  
			- Range 0,5 - 800 mm 
			- Accuracy 2 - 2000 µm 
			- Resolution 1 - 100 µm 
			- Contactless through triangulation 
			 | 
		
		
			|   | 
		
		
			| 
			   
			 | 
			
			 Digital Magnetic Scale 
			  
			- Range 50 mm - 50 m 
			- Accuracy 10 - 100 µm 
			- Resolution 0,1 - 5 µm 
			- Output A/B u. Ref., TTL, Vss 
			- Contactless through magnetic floater 
			 | 
			  | 
			
			   
			 | 
			
			 Digital Gauge 
			  
			- Range 5 - 205 mm 
			- Accuracy 1 - 10 µm 
			- Resolution 0,2 - 5 µm 
			- Output A/B u. Ref., TTL 
			- Measurement through sprung loaded push rod 
			 | 
		
		
			|   | 
		
		
			| 
			   
			 | 
			
			 Digital Ruler 
			  
			- Range 15 - 2170 mm 
			- Accuracy 2 - 10 µm 
			- Resolution 0,1 - 5 µm 
			- Output A/B u. Ref., TTL, Vss 
			- Measurement through reading head 
			 | 
			  | 
			
			   
			 | 
			
			 Linear Potentiometer 
			  
			- Range 10 - 2000 mm 
			- Accuracy 0,05% - 0,2% 
			- Resolution k. A. 
			- Output potentiometrisch 
			- Measurement through guided/sprung loaded/slider/ring 
			 | 
		
		
			|   | 
		
		
			| 
			   
			 | 
			
			 Magnetostrictive 
			  
			- Range 50 - 4000 mm 
			- Accuracy 0,02% - 0,1% 
			- Resolution 1 - 100 µm 
			- Output 10V, 4-20mA, Tacho, Start-Stop, PWM, Profibus 
			- Contactless through floating cursor or ring magnet 
			 | 
			  | 
			
			   
			 | 
			
			 Ultrasonic 
			  
			- Range 100 - 6000 mm 
			- Accuracy 0,7% - 1,5% 
			- Resolution 1 - 3 mm 
			- Output 5V, 10V, 4-20mA 
			- Contactless through ultrasonic sound reflection 
			 | 
		
		
			|   | 
		
		
			| 
			   
			 | 
			
			 Display + Control 
			  
			- Multifunctional display 
			- Input analog/digital 
			- 1 - 10 channels 
			- Built in and external units (miller/lathe) 
			- Distance and velocity, comparator... 
			 | 
			  | 
			
			   
			 | 
			
			 Angle Transmitter + Encoder 
			  
			- Single and multiturn 
			- Analogue and digital transducer 
			- Solid shaft/hollow shaft 
			- Output A/B/Z, CAN, Profibus, 10V, 4-20mA, 1k 
			- Rotational measurement 
			 |