Instantaneous relays 1 contacts / BIV-105
Description
 
Monostable instantaneous relay. 1 RT - 10 A
BIV-105 are terminals for mounting onto rails of 35 mm or G.
They are characterized by a compact conception incorporating an instantaneous relay 1 RT - 10 A.
Its special character makes it a basic element for system interfaces realization. 
 
Dimensions

 
Connection

 
 
Technical features
	
		
			| Function | Instantaneous | 
		
			| Presentation | Under case | 
		
			| Connection | onto rails C or G | 
		
			| Number of mechanical operations | 5.000.000 | 
		
			| Operating temperature | -30° C +40° C | 
		
			| Climatic protection | Reinforced climatic protection | 
		
			| Shock voltage | 3 000 V crête | 
		
			| Dielectric strength | between coil and contacts - 2 000 V eff | 
		
			| Insulation resistance | > 1000 MOhms | 
		
			| Operate time | DC: 10 ms AC: 12 ms | 
		
			| Release time | DC, AC: 5 ms | 
	
 
Coil data
	
		
			|  | Direct current | Alternative current | 
		
			| Min. nominal voltage DC | 6 - 12 -24 - 48 - 125 V | 12 - 24 - 48 - 120 - 230 V | 
		
			| Power requirement | 0,6 W to1,2 W | 0,6 VA to 2,6 VA |  | 
	
 
Contacts
	
		
			| Number of contacts | 1 | 
		
			| Max. load current | 10 A | 
	
 
   
  
  
  - Flashing relays 2 contacts / Model CAK- Flashing relay with fixed rythm - 2 CO contacts - 5 A.
Pluggable on socket with a withdrawal clasp and square guide pins which can act as a key to ensure that the correct relay is used at the correct voltage (see our withdrawal guide inthe technical support pages of this site).
Pluggable on the following sockets : EVB2/CA, ERC2/CA and ERDL2/CA. 
 
- INSTANTANEOUS AND FUNCTION RELAYS 2 contac  / Model CSP- Impulse relay with fixed duration - 2 CO contacts - 6 A.
CSP relay is equipped in its standard version of : a locking system with elastic clips on the basis and clasps on the cover, two hexagonal withdrawal clasps permitting up to 36 possibilities (voltage, function) and a removable label-holder on front face.
Pluggable on the following sockets : SVB, SPVB, SVDL, SPVDL, SRDL 4,8 and SRC. 
 
- Instantaneous relays 2 contacts / Model CAQ- MTI Instantaneous relays 2 contacts / CAQ  Instantaneous relay with rapid memory,
Pluggable on socket with a withdrawal clasp and square guide pins which can act as a key to ensure that the correct relay is used at the correct voltage 
 
- Instantaneous relays 2 contacts / Model 1902- 1902 interface module, 2 RT - 5 A
this interface module has a red indicator led (3mm diameter).
The terminal max. width is 18mm, except for 220 V AC version which has 23mm of width.
1902 module fixing is adapted for symetricals and asymetricals din rails. 
 
- Instantaneous relays 2 contacts / Model 1210- Tec-Automatismes Model  1210 ınstantaneous relays, model 1210 2 contacts ınstantaneous relays 2 contacts,Instantaneous relays 
2 contacts 
1210 series
Instantaneous relay 2 or 3 CO contacts.
Pluggable on front wiring socket (9215) or rear wiring socket (9210) - 8 or 11 pins