Pavone Sistemi Load Cells Compressio CC3
- The CC-3 load cell has been designed to meet the requirements of a wide range of applications for industrial weighing
- ATEX (option)
- Double bridge version, exit 8-conductor shielded cable (option)
- The low profile pattern and small-size dimensions require a very contained mounting space
- Good characteristics of precision and sturdiness
- The CC-3 is made of stainless steel to ensure maximum impact and overload resistance
- Temperatura compensation up to 120°C on request
- The CC-3 load cell has been designed to meet the requirements of a wide range of applications for industrial weighing
- ATEX (option)
- Double bridge version, exit 8-conductor shielded cable (option)
- The low profile pattern and small-size dimensions require a very contained mounting space
- Good characteristics of precision and sturdiness
- The CC-3 is made of stainless steel to ensure maximum impact and overload resistance
- Temperatura compensation up to 120°C on request
CAPACITY |
ØA |
B |
C |
ØD |
ØE |
F |
G |
0.1÷10t |
82 |
44 |
32 |
22 |
70 |
22 |
M8x15 |
15÷20t |
100 |
48 |
35 |
28 |
80 |
22 |
M10x15 |
25÷35t |
126 |
54 |
40 |
35 |
105 |
22 |
M12x20 |
50÷100t |
165 |
85 |
60 |
60 |
130 |
22 |
M16x20 |
200t |
200 |
85 |
60 |
85 |
165 |
22 |
M16x20 |
Electrical Connections |
+Excitation |
Red |
-Excitation |
Black |
+Signal |
Green |
-Signal |
White |
Shield |
Cable Shield |
TECHNICAL CHARACTERISTICS CC3
Rated load (RL): |
0.1÷10, 15, 20, 25, 35, 50, 100, 200 t |
Combined error: |
< ±0.05% of R.O. |
Repeatability: |
< ±0.02% of R.O. |
Creep (20 minutes): |
< ±0.02% of R.O. |
Safe overload: |
150% of R.L. |
Ultimate overload: |
300 % of R.L. |
Recommended input: |
5÷15 Vdc/Vac |
Input resistance: |
700 ±10 Ohm |
Output resistance: |
700 ±3 Ohm |
Insulation resistance: |
> 2000 M Ohm |
Rated output (R.O.): |
2.0 mV/V |
Zero balance: |
< ±1% of R.O. |
Temperature range: |
-20 ÷ +70 °C |
Compensated temperature range: |
-10 ÷ +50 °C |
Temp. effect (-10° to +50°C) on zero balance: |
0.003% of R.O./°C |
Temp. effect (-10°C to +50°C) on output: |
0.002% on output/°C |
Electrical connection: |
4 conductors shielded cable; length 5 m |
Protection Degree |
IP 68 |
CAPACITY |
A |
B |
C |
D |
E |
F |
G |
H |
0.1÷10t |
175 |
95 |
115 |
10 |
- |
150 |
14 |
M12 |
15÷20t |
200 |
102 |
160 |
10 |
35 |
12 |
17 |
M12 |
25÷35t |
250 |
132 |
185 |
12.5 |
61 |
12 |
20 |
M18 |
50÷100t |
320 |
155 |
250 |
15 |
70 |
15 |
23 |
M20 |
MEGATRON Elektronik S-Beam Series KT1401MEGATRON Elektronik S-Beam Series KT1401 Ürünleri ile uygun rekabetçi fiyaları almak için müşteri temsilçimiz ile http://www.imajteknik.com.tr/bize-ulasin veya Fiyat teklifi formunu doldurarak mesaj bırakmanız halinde satış muhendislerimiz en kısa zamanda sizinle irtibat kuracaklardır.,Series KT1401 force transducer are very compact models and do not differ in their dimensions over all offered capacities. Because of their shape (S-Beam) this force transducers are recommended for applications with tension force especially. Force is applicated by M8 internal screw thread. DMS Wheatstonebridges (measuring principle) have delivered an optimal performance since decades and ensures a long lifetime.
MEGATRON Elektronik Shear Beam Series KT701MEGATRON Elektronik Shear Beam Series KT701 Ürünleri ile uygun rekabetçi fiyaları almak için müşteri temsilçimiz ile http://www.imajteknik.com.tr/bize-ulasin veya Fiyat teklifi formunu doldurarak mesaj bırakmanız halinde satış muhendislerimiz en kısa zamanda sizinle irtibat kuracaklardır.,Series KT701 force sensors are double bending beam sensors and characterized by its tight shape and its easy way of fastening. It could be fixed with 2 screws at any flat and stabil ground. Force application is vertical to sensor-axis.
Compression load cell TSL – From 5 to 30 tPRECIA MOLEN COMPRESSION LOAD CELL TSL – FROM 5 TO 30 T
The TSL load cell is a low profile compression load cell made of welded hermetically sealed stainless steel.
Precision up to ± 0.05%. Spherical load button for optimum alignment of the load.
Allowable forces on the kit:
The maximum static horizontal force along the centre line of the locking strip (1) is 8 kN.
The maximum vertical tear off force is 20 kN for the 15 t kit and 35 kN for the 30 t kit.