Instantaneous relays 
Model 1210 
2 contacts
Instantaneous relays 2 contacts / 1210
 
	
		
			|  |  |  
 1210
 
 rear wiring socket to be soldered 9210-30
 rear wiring socket to be soldered 9210-20
 front wiring socket / screw terminals 9215-30
 front wiring socket /screw terminals 9215-20
 | 
	
 
	
		
			|  | DESCRIPTION | 
		
			|  | Instantaneous relay 2 or 3 CO contacts.
 Pluggable on front wiring socket (9215) or rear wiring socket (9210) - 8 or 11 pins
 
 Detailed table with coil resistance data is available in the technical support pages of this site or can be sent upon request.
 | 
	
 
 
	
		
			|  | Dimensions |  | Connection | 
		
			|  |  |  |  | 
		
			|  |  |  |  | 
	
 
 
	
		
			|  | TECHNICAL FEATURES | 
		
			|  | Function | Instantaneous | 
		
			|  | Presentation | under cover | 
		
			|  | Connection | on front or rear wiring sockets | 
		
			|  | Number of mechanical operations | 10.000.000 | 
		
			|  | Operating temperature | - 10 to + 55°C | 
		
			|  | Storage temperature | - 40°C to + 80°C | 
		
			|  | Climatic protection | reinforced climatic protection | 
		
			|  | Shock voltage | 50 g - 11 ms | 
		
			|  | Dielectric strength | 2 KV-50 Hz-1 min at 40°C and 70% HR | 
		
			|  | Insulation resistance | > 200 MOhms | 
		
			|  | Weight | 94 g. | 
	
 
 
	
		
			|  | COIL DATA | 
		
			|  |  | Direct current | Alternative current | 
		
			|  | Min. nominal voltage DC | 6 V | 6 V - 50 or 60 Hz | 
		
			|  | Min. nominal voltage AC | 220 V | 400 V - 50 or 60 Hz | 
		
			|  | Operating range | -20/+10% of nominal voltage | 
		
			|  | Power requirement | 2 RT : 0,25 W - 3 RT : 0,5 to 2,2W | 3 to 4,5 VA | 1,6 to 3 VA | 
	
 
 
	
		
			|  | CONTACTS | 
		
			|  | Number of contacts | 2 or 3 RT | 
		
			|  | Contacts material | silver alloy with gold flash | 
		
			|  | Max. load current | 8 A per RT | 
		
			|  | Low power switching | 150 mA with min voltage 5 V and/or I min 40 mA | 
		
			|  | Short-circuit load | 250 A / 30 ms | 
		
			|  | Response time | DC < 13 ms - AC < 20 ms | 
	
 
 
	
		
			|  | CONTACTS RATING | 
		
			|  | 
		
			|  | DIRECT CURRENT | 
		
			|  | 
				
					
						| resistive load |  | inductive load - cos phi = 0,7 |  
						|  |  |  |  
						|  |  |  |  | 
		
			|  | 
		
			|  | ALTERNATIVE CURRENT | 
		
			|  | 
				
					
						| resistive load |  | inductive load cos phi = 0.7 |  
						|  |  |  |  
						|  |  |  |  | 
	
 
 
	
		
			|  | VERSIONS | 
		
			|  | Wide range of coil consumptions : from 0,25 to 2,2 W in DC current and from 1,6 to 3 VA in AC current. Please contact us. | 
	
   
  
  
  - Instantaneous relays 2 contacts / Model 1902- 1902 interface module, 2 RT - 5 A
this interface module has a red indicator led (3mm diameter).
The terminal max. width is 18mm, except for 220 V AC version which has 23mm of width.
1902 module fixing is adapted for symetricals and asymetricals din rails. 
 
- INSTANTANEOUS AND FUNCTION RELAYS 2 contac  / Model CSP- Impulse relay with fixed duration - 2 CO contacts - 6 A.
CSP relay is equipped in its standard version of : a locking system with elastic clips on the basis and clasps on the cover, two hexagonal withdrawal clasps permitting up to 36 possibilities (voltage, function) and a removable label-holder on front face.
Pluggable on the following sockets : SVB, SPVB, SVDL, SPVDL, SRDL 4,8 and SRC. 
 
- Instantaneous relays 2 contacts / Model CAQ- MTI Instantaneous relays 2 contacts / CAQ  Instantaneous relay with rapid memory,
Pluggable on socket with a withdrawal clasp and square guide pins which can act as a key to ensure that the correct relay is used at the correct voltage