PRECIA MOLEN Shear beam load cell CMI – from 500 to 5000 kg
GENERAL INFORMATION
The CMI load cell consists of a stainless steel body and is hermetically sealed by laser welded stainless steel cups. It has been designed for use in industrial environments with an aggressive atmosphere, such as the chemical industry. CMI load cells have a test certificate for 3 000 d. Meeting the IP 68 standard, CMI load cells are compact and available in four capacities: 500, 1 000, 2 000 and 5 000 kg.
Special mounting parts to adapt the load cell to its mechanical environment are available as an option.
DESCRIPTION
The working principle of the CMI load cell is to measure the deformation of a beam subjected to shear stress. The strain gauges are arranged to form a Wheatstone bridge, converting the mechanical force exerted on the load cell into an electrical signal.
CONFORMITY
Test certificate issued by a notified body in accordance with OIML recommendation R60.
EX OPTIONS
Ex version for use in explosive zone according to new directive 94/09/CE
CE EEx ia IIC T6
CE type certificate Nr : LCIE 02 ATEX 6083 X
MEGATRON Elektronik S-Beam Series KT1502MEGATRON Elektronik S-Beam Series KT1502 Ürünleri ile uygun rekabetçi fiyaları almak için müşteri temsilçimiz ile http://www.imajteknik.com.tr/bize-ulasin veya Fiyat teklifi formunu doldurarak mesaj bırakmanız halinde satış muhendislerimiz en kısa zamanda sizinle irtibat kuracaklardır.,Series KT1502 force sensors are easy to integrate by internal screws.
Digital compression load cell ASL – 50tPrecia-Molen Digital compression load cell ASL – 50t
The ASL is a digital compression load cell based on single column technology particularly suitable for weighing applications on weighbridges.
It is made of stainless steel and is compact, and sealed under prolonged immersion (IP 68).
Compression load cell SCL – From 35 to 55 tPrecia-Molen Compression load cell SCL – From 35 to 55 t
The measurement principle used in the SCL load cell is based on the deformation of beams to which a compression force is applied. It uses strain gauges arranged to form a Wheatstone bridge for conversion of the force to an electrical signal. The SCL load cell is specially designed to be insensitive to excentrical loads while remaining compact.